Ademco V15P60VATKT Vista-15P-6160 KIT
Kit Includes:
1-Vista 15P.
1-6160 Alpha Keypad.
1-5881ENM
1-Wave 2 Siren.
1-Aurora 40 LB Pet Motion
1-Transformer.
1-Battery.
1-RJ-31X Telephone Interface Jack.
Vista 15P
Installation Instructions
Vista 15P User
Instructions

Also
See Ademco 5800 Series Wireless Equiptment & Accessories.
Six hardwired zones
Expands to 32 total zones (up to 26 wireless and/or 14 hardwired zones)
16 user codes
48 event log with date/time stamp
Two-wire or four-wire smoke detectors
Fast and easy E2 programming mode
Features
Six on-board hardwired zones
– Hardwire expansion up to 22 zones
– Wireless expansion up to 26 zones
Eight independent keyfob zones allow wireless keys to be programmed
without using any of the 22 zones
Six on-board hardwired zones standard
Expandable to 32 total zones when used with hardwired and/or
wireless expansion modules
Hardwire expansion up to 16 zones Wireless expansion up to 26
zones
Wireless Keys can be programmed without using zones
Eight output devices
– Relays (Model 4204 Relay Modules - or 4229 Expansion Module) - and/or
– X-10 ® devices (when used with a 4300 Transformer)
Two low current on-board trigger outputs
50 Event Log viewable at system keypads with time/date stamp
32 system user codes
Two installer configurable zone types allows the installer to
(create custom zone types) by assigning all zone attributes
Multiple actions on output devices depending on system (state)
– Turns light off when system arms
– Turns same lights on when system disarms
– Flashes same lights when system is in alarm
Built-in phone line cut monitor with programmable delay and
annunciation options
– Display on system keypads
– Trigger local sounders
– Trigger system bell
Supports four-wire, and up to 16 two-wire smokes
– Works with Sentrol CleanMe™ maintenance signal
Valuable End-User Features
Now viewable on system keypads:
– Exit countdown
– Time and date display*
– Event log*
Auto keypad backlighting on entry
Keyswitch arming
Programmable macro buttons and single-button arming
A variety of wireless remote controls for single-button operation
User Scheduling
– Automatically activates X-10 and relays at programmed times
– Latchkey reports to pagers
– Auto arm/disarm
– (User access) time windows
Supports up to two numeric pagers
VIP Module allows system control from any touchtone phone
Chime by zone
*Requires custom alpha keypad
|
UL approved
for ANSI/SIA
CP-01-2000 |
Security Dealer Features
False alarm prevention features help reduce false alarms
Automatic System Load Shed
– During extended AC power fail - the system battery will be disconnected to prevent
irreversible battery failure. Reduces service calls to replace batteries
Dynamic Signaling
– Reduces redundant reporting to the central station when multiple reporting methods
are used; i.e. digital dialer and AlarmNet Radio
Specifications
Electrical
Aux. power 12VDC - 600mA maximum
Seven hour standby at 400mA aux. load with four amp hour battery
16.5VAC/25VA transformer
Alarm output 12VDC - 2.0 amps maximum
For UL installations - combined aux. and alarm output cannot
exceed 700mA
Output Control
Zones
Six hardwired zones
Selectable response: 10msec - 350msec - 750msec
16 selectable zone types plus two configurable zone types
Programmable swinger suppression
Expansion Devices
4219 – Eight hardwired zones – 16mA
4204 – Up to four relays – 15mA standby (each active
relay draws an additional 40mA)
4229 – Eight hardwired zones and two relays – 36mA
(each active relay draws an additional 40mA)
Accessories
4286 VIP Voice Module – 220mA
5881ENL supports up to eight zones – 60mA - 5881ENM supports
up to 16 zones – 50mA - 5881ENH supports up to 26 zones – 50mA
5883 Transceiver supports up to 26 zones – 80mA
Supports Eagle 1225 and 1221 boards
Keypads
Agency Listings
Smoke Detectors
Communications
Touchtone or pulse
Formats supported
– ADEMCO Contact ID
– ADEMCO 4 + 2 Express
– ADEMCO low speed
– Sescoa/Radionics
3 + 1 - 4 + 1 and 4 + 2 reporting
Reporting capabilities
– Split
– Dual
– Split/Dual – True dial tone detection
Low battery reports 11.2 – 11.6VDC
AC loss and restoral reporting supported
|