Ademco
Part #: 7845CZ

Ademco 7845CZ 7 Zone Alarmnet Nationwide Radio

List Price: US$303.50
Your Price: US$242.80


Complete Description Below:


 
New Page 1
This Radio can connect you to central station nationwide.
Has 7 Zones You Can Setup Using Your Systems Relay Outputs. Fully Programmable.
Interfaces with all burglar alarm systems.
When using Ademco This Radio Sends contact id just like the built in digital that comes with most ademco systems.
We must program the radio for you before we ship it.
PLEASE CALL FOR SIGN UP INFORMATION-800-309-1009

Control Channel Cellular Transceiver

By using cellular control channels - the 7845C offers virtually limitless coverage. The 7845C communicates on the Cellular Network’s Control Channel. Alarm and status packets are transmitted into the cellular network control channel where they are identified and routed to the AlarmNet Control Center. The AlarmNet Control Center logs status checks and routes alarms via RF to any AlarmNet equipped Central Station anywhere in the country. There is no cellular phone call required and no system busy conditions to deal with. It is fully supervised by AlarmNet and there is a low fixed monthly charge for normal traffic. There is no additional hardware or software required in Central Stations already equipped to receive AlarmNet. The transceiver connects to most ADEMCO alarm control panel.

A security system’s most vital link — the telephone line — is also its most vulnerable. Count on AlarmNet ... the most highly effective alternative second line or backup to alarm transmission over phone lines. The wireless communications service works with existing security systems to assure that alarm signals get through — no matter what.

Easy to install.

New Business Opportunities
  • Maximize recurring revenue
  • Provide your customers with the ultimate protection
  • Keep the competitive edge
AlarmNet-C Benefits
  • Nationwide coverage
  • Low-cost
  • Quick - easy installation
  • Highest level of reliability
  • No busy signals or cloning

Radio features:

  • Low cost
  • Compact size
  • Powered from the panel
  • Nationwide cellular system coverage
  • Interfaces with ADEMCO alarm control to the AlarmNet radio network for alarm signal transmission
  • Seamless - wireless connectivity through cellular networks - to AlarmNet equipped Central Stations
  • Timed status check-in for radio link supervision
  • Built in signal strength meter
  • Choose between one of 4 modes: Contact ID - Zone - Relay Emulation Mode or 4229 Mode

Applications:

Provides the highest level of security available.You can connect the 7845C to almost any security system to transmit alarms and supervisory signals to the Central Station in the event telephone service is interrupted.

  • Back-up to phone line interruption
  • Seamless - wireless connection to AlarmNet equipped Central Stations
  • Battery backup
  • Automatic cover and antenna tamper protection
  • Household burglary - UL1023
  • Central station burglary - UL1610
    - Grade A
    - Grade B
  • Police connect burglary - UL 365
    - Grade A
  • Contact ID when connected to appropriate ADEMCO control panel

Installation:

After the radio is powered up - the LED should be observed to determine the optimal installation location. The installation LED will indicate signal strength - network contact and installation suitability. The radio is wired to the panel per wiring diagram provided with the radio. It can be installed close to or inside the panel itself. Installing 7845CZ within the panel may require the use of external antenna 7825OC. The radio is mounted according to the mounting instructions noting that the antenna must be vertical. Radio should not be mounted where it would be obstructed by a steel structure or security doors and windows which may be pulled down at night.

Programmable Features:

Zone Mode:

  • 1 input:
    - 2K EOL supervised configurable for either voltage or ground trip
  • Zone Mode/Radio Fault Output: Open collector ground trigger (programmable for fail-safe)

Programmability:

  • Pulse steady bell detection (fire/burg) (not for UL installation)
  • Restoral reporting
  • Delayed reporting
  • Dual central station reporting
  • Supports silent panic for LYNX products

Serial Mode:

  • Simple 4 wire connection to certain VISTA controls using the keypad bus.
  • Fully supervised connection between control and radio
  • Full contact ID reporting on certain ADEMCO controls
  • Programmable relay emulation mode
    - Provides connectivity to ADEMCO panels not supporting radio ECP
    - 4 zones

Other Features:

  • Integrated smart swinger suppression
  • Integral tamper switch: Dual function tamper switch for cover tamper detection, and installation test functions
  • Power fail detection/reporting
  • Low battery/battery condition reporting
  • 4229 zone expander option
    - Add up to 7 zones on any panel

SPECIFICATIONS:

ELECTRICAL

Power
Powered from panel @ 150mA max.
Optional 12.5VDC @ 3AMP DC power pack

Battery Backup
Burg: 6V 0.5Ah rechargeable sealed lead acid battery

Current Requirements
90 mA normal operation; 400mA peak during transmission

MECHANICAL

Dimensions
4 Inch W x 6.5 Inch H x 1.5 InchD (without antenna)

Operating Temp
-30° to +60° C

Humidity
0% to 90% non-condensing

TRANSCEIVER
MicroBurst™ Compatible Cellular Radio

RF Power Output: 0.6 watts

Frequency Band
- 833-835 MHz Transmit
- 878-880 MHz Receive
Channel Separation: 30 kHz
Receiver Sensitivity: -115 dBm

Antenna: 5/8 wave helical unity gain

Serial Mode: Radio faults are reported to the panel on the serial link

LED Indicators
3 status LED's visible when cover is on:
- Network connection status
- Power status
- Alarm delivery status

7 installation and set-up LED's visible when cover is off:
- Signal strength
- Installation suitability
- Operation mode

Zone Inputs and Alarm Functions:
Reporting format in zone mode: ADEMCO High Speed
Reporting format in serial Mode:

- ADEMCO contact ID on certain ADEMCO control

- Relay emulation mode in ADEMCO high Speed

- 4229 mode in ADEMCO high speed

 

 

 