New Page 1
Ademco 5140DLM Dual Telephone Line Module Connections
For Use With The Vista 32FB - 100 - 128
- 250.
Connect the main dialer and backup dialer (if used) outputs to telephone
company lines, which provide loop start service using the RJ31X Cables supplied. Do not connect to
telephone company lines that provide ground start service.
The 5140DLM Backup Dialer mounts to the main PCB shield and connects to
the main PCB J3 connector using a ribbon cable (supplied with module (Part# N3101E09) as
shown in the Summary of Connections diagram at the end of this manual.
Connect the earth ground screw on the 5140DLM to the earth ground screw
(terminal 30) on the main PCB using 16 AWG wire.
Cut the blue jumper when the dialer outputs are connected to telephone
lines, which have a telephone company MTU installed.
|