DSC Power Series Security Systems
DSC
POWER 608 6 to 8 Zone Hybrid Security System
DSC
POWER 832 8 to 32 Zone Hybrid Security
System
DSC
POWER 864 8 to 64 Zone Hybrid Security
System
DISCONTINUED OFF THE SHELVES: Although we
still have stock because we bought them out.
PC5921
PC5921EXT
PC5921EXTR
PC5928
PC4937
This remarkable system has the
power to protect you...
The security system that keeps you safe in
so many ways
It used to be that a burglar alarm was all
you needed to feel safe. Well, times have
changed. And so have your security options.
In keeping with new times and new
technologies, at
SC
we've redefined the meaning of security. And
we've translated this broader definition
into a powerful new system that will keep
you and your family safe...in ways you never
imagined. Introducing Power Series... from
DSC. A security system that is more than a
burglar alarm. A reliable, easy to use,
affordable system that will offer you peace
of mind for years to come.
7 Station Intercom
Power Series offers so many new and exciting
ways to keep you and your family safe. Our 7
station intercom allows you to listen to the
baby sleeping in the nursery, and
communicate with your children in the
playroom while you work in your 2nd floor
office. Talk to people at your door without
having to open it.
All this security...and hands-free too.

Classic Keypad |
Remote Telephone Access & Home Automation
Control your own Power Series using any
touch-tone telephone in the world and DSC's
Voice Assisted Security Control. The voice
gives you complete status of your system and
allows you to make changes, disarm your
system and control 32 automatic devices such
as heating, lighting, locks and gates.
Paging
Can't be home to greet the kids after
school? Would like to track the number of
hours your housekeeper spends in your home?
Have peace of mind knowing that your system
will page you the minute your kids walk
through the door. Or when your housekeeper
leaves for the day. Power Series offers
different codes for different needs to suit
your own personal lifestyle.

Delux Keypad 8 to 32 Zones
|
Easy To Use
A security system is only effective if it's
a cinch to use. Power Series offers 5 one -
touch function keys with one word commands.
So when you're rushing out the door, the
push of a single button will ensure your
home is safe and sound. And with Power
Series's special 'Exit' button, there's no
need to disarm or rearm the system every
time you leave the house or let the dog out.

English Language LCD Keypad
|
SPECIFICATIONS
Power608 6 zones Hardwired expandable to 8
zones hardwired or wireless.
Power832 32 Zones Hardwired or Wireless … 2
Partitions
Hardwired 8 zones on main panel
PC5108 - 8 zone expansion module
PC5108L - 8 zone expansion module plus
Downlook video on Power Series PC5015 panel
The Power Series system is fully
programmable from any of the attractive,
easy to use, LED keypads or the alpha
numeric LCD Keypad

Fixed Message LCD Keypad
|
4 keypads available :
PC5508Z ........ 8 zone LED keypad
PC5516Z ........ 16 zone LED keypad
PC5532Z ........ 32 zone LED keypad
LCD5500Z ...... English Language LCD Display
LCD5501Z ...... Fixed Message LCD Display
LCD5501ZINT .. Icon LCD Display

Icon LCD Keypad |
Each of the above keypads feature;
-Zone input -connect detector to keypad to
avoid separate wiring back to panel
-Rotating keypress buffer reduces access
code entry false alarms
-5 programmable function keys with 25
options such as Home Arm, Away Arm, Quick
Exit etc.
-LED indicators : Ready, Armed, Trouble,
Memory, Bypass, Fire, Program
-4 keypad-activated alarms…Panic, Auxiliary,
Fire, and Duress
-Backlit display…with Backlighting Boost to
provide extra high key lighting when any key
is pressed
-Piezo buzzer…provides audible feedback for
correct key entries, pre-alert, and system
trouble status… with adjustable buzzer tone
-Up to 12 Keypads comprised of up to 8
hardwired keypads and 4 wireless keypads
-Connect to 4 wire KEYBUS up to 1000' (305m)
from control panel
-Current draw : 85mA with backlighting boost
-Dimensions : 5.75" W x 4.5"H x 1" D (144 x
114 x 25mm)
PC5400 - Printer Interface Module
-provides RS232 serial printer connection
for report of events logged to the system
event buffer… -prints event, partition,
time, and date that event occurred
-supports any 300, 1200, 2400 or 4800 BPS
serial printer
-connect printer up to 200' (61m) from
PC5400
-connect PC5400 up to 1000' (305m) from
control panel via KEYBUS
-current draw : 65mA @ 12VDC
-maximum one module per system

8 input zone expander
|
Hardwired Expansion
PC5108- 8 Zone Expansion Module adds 8
hardwired general purpose burglary or fire
zones
provides 100mA @ 12VDC auxiliary current,
PTC protected connect up to 1000' (305m)
from control panel via KEYBUS module current
draw : 35mA @ 12VDC
Wireless Expansion

Wireless sensors
|
PC5132 Wireless Receiver add up to 32 DSC
wireless detectors * including :
-WLS904 ........ passive infrared detector
-WLS906 ........ photoelectric smoke
detector
-WLS907 ........ slim-line transmitter
-WLS912 ........ glass break detector
-WLS914 ........ pet immune PIR
-WLS915 ........ door/window contact
* standard Eveready Energizer® alkaline
batteries

Wireless receiver
|
900 MHz true 'Spread Spectrum' technology,
fully supervised for communication
integrity, easy sensor enroll process,
supervisory transmissions every 12 minutes,
programmable 1-24hr supervisory window,
connect up to 1000' (305m) from control
panel via KEYBUS module, current draw :
130mA @ 12VDC

Wireless control
|
Wireless Control Devices
WLS908 Wireless Panic Pendant
-communicates a non-medical alarm to central
station
-32 pendants maximum…each occupying 1 alarm
zone
-sealed non-replaceable battery
WLS909 Wireless Key
-remote arm/disarm control
-up to 16 keys per system
-3 photo/electronic 1.5 V batteries included
WLS910 Wireless Hand-Held Keypad
-personal remote keypad
-up to 4 wireless keypads per system (in
addition to hardwired keypads)
-3 'AAA' batteries included

Keypad emergency buttons |
Addressable Multiplexed Detectors
Addressable Multiplex technology is
available by the use of the PC5200 Expansion
module. The 5200 can connect up to 32 zones
(sensors) to the control panel via a single
figure 8 cable.
This figure 8 cable is used as a
communication bus and each detector simply
connects to it in parallel. The cable also
supplies power to each sensor. The specially
designed sensor cantains a digital
transmission circuit that will transmit
alarm, restorals, tamper and service
information to the control panel. Each zone
(sensor) has an individual address so that
the control panel can interpret individual
sensor data. The panel continuously polls
each device on the addressable connection
many times per second, providing excellent
protection against sensor tampering. Each
sensor draws around 3.5 to 4 milliamps of
current and therefore many sensors can be
installed to a single cable run. The major
advantage of addressable multiplex
technology is that there are huge savings in
installation costs due to a reduction of
cable, conduit and ducting requirements and
also installation labour. For further
information of the DSC range of addressable
sensors, click
here.

Voice prompt remote control.
|
Integrated Voice Assisted Security & Home
Automation
ESCORT 5580 Voice Assisted Security &
Automation Control Module turns any
touch-tone phone into a fully functional
keypad with Global and Partition control
built-in power line interface for control of
32 X-10 automation control devices
-16 schedules with On Time, Off Time, and
Day of Week
-8 user controlled automation modes
-full range of dimming levels for lighting
control
-event activated control for any PGM output
supported by the main panel
An extensive library of voice prompts for
security and automation operation,
programming, and system status feedback
-250 system words for pre-programmed system
functions
-240 word library for user programmable
voice prompts for Automation Item Labels,
Automation Mode Labels, -Partition Labels,
and Zone Labels
-Program up to 6 words per voice label
-Powerful 'say number' command can announce
numbers from 0-999 in three different ways
-Connect up to 1000' (305m) from control
panel via KEYBUS
-Module current draw: 150mA @ 12VDC

Intercom door station
|
Integrated Intercom Audio Interface
Supports Central Station Two Way Voice and
Home Intercom features using PC5928 audio
interface module, PC5921 intercom stations,
and PC5904 two way listen-in stations
PC5921 Internal Intercom Station
PC5921EXT…external intercom station
PC5921EXT/R…external intercom station with
relay for operation of existing door bell
PC5928 Audio Interface Module
-provides 7 output ports for connection of
PC5921 Series Intercom Stations
-connect up to 1000' (305m) from control
panel via KEYBUS
Local intercom functions :
-page/answer
-do not disturb
-doorbell function
-door strike release
-listen-in broadcast …allows any station to
be programmed as a 'broadcast station' to
which all other internal stations in the
system may listen in
-programmable as sounder for fire/burglar
alarms
-answer telephone calls received on regular
voice line
-ringing programmable by station
-supports call waiting
-allows call transfer to in-house phones

Downlook video verification
|
Integrated CCTV
PC5108L Downlook Interface Module
***for PC5015 only ***
Provides an interface between the PC5015
alarm control panel and the Downlook DLM-4
still frame video transmission module
communicates alarm followed by video over a
single telephone line in one transmission to
a Sur-Gard MLR2 digital receiver
- 8 inputs for video cameras, VCRs, or video
switchers
-8 general purpose burglary or fire alarm
zone inputs
-any alarm zone (up to 32) or group of zones
can be programmed to initiate video capture
of 4 frames from any 4 sources - in any
sequence
-programmable on-site sequential video
switcher mode
-view and capture images on a monitor / VCR
setup
-select cameras for viewing manually using
an LED keypad or program system to switch
automatically between -selected cameras at
programmed dwell times supervised by main
panel
-programmable via downloading using modem or
direct PC-Link
-connect up to 1000' (305m) from control
panel via KEYBUS
-module current draw : 60mA @ 12VDC
PGM Output Expansion
PC5204 Power Supply/ High Current Output
Module provides 1A @ 12.5VDC auxiliary power
for additional modules and devices
includes 4 fully programmable high current
outputs
-rated at 1 A @ 12VDC, PTC protected
-will provide 3 A short term if battery
backup connected
-each output can sink up to 3A
-output #1 may also be used as a supervised
bell output
-700mA max
-each output programmable to activate for
any of 24 options
-connect up to 1000' (305m) from control
panel via KEYBUS
-fully supervised for : tamper, low battery,
AC power loss, and auxiliary power trouble
-maximum 1 module per system
-module current draw : 20mA @ 12VDC
-battery required : 4Ah minimum
-transformer required : 16.5VAC, 40VA
PC5208 Low Current Output Module
module provides 8 low current transistor
switch outputs
-each output can sink up to 50mA
-up to 250mA max at one time
-each output programmable to activate for
any of 24 options
-connect up to 1000' (305m) from control
panel via KEYBUS
-fully supervised for tamper
-maximum 1 module per system
-module current draw : 20mA @ 12VDC
Advanced Communications digital
communicator
-supports all major formats including SIA &
Contact ID
-supports LINKS1000™ cellular communications
-supports LINKS2150™ and LINKS2450™ long
range radio communications
-3 phone numbers (3rd backs up primary)
-2 account numbers
-DTMF or pulse dialing
-DPDT line seizure
-anti-jam feature
-split reporting of selected events to each
telephone number
-event initiated personal paging
-Downlook video transmission using PC5108L
module on Power Series PC5015 main control
panel
Zone programming
-all zones programmable as burglary or fire
-zone options include : Normally Closed
loop, Single End of Line (EOL) resistor, and
Double EOL resistor *
-27 programmable zone types, 8 programmable
zone options
Audible alarm output
-supervised bell output - 700 mA @ 12VDC,
PTC protected, current limited at 3 A
-steady, pulsed, temporal pattern, or strobe
fire output
-additional supervised siren output is
available using PC5204 power supply module

Keypad single
touch function
buttons |
Remote upload/download capability
-program system using DLS software via
remote PC over telephone line
-view status and trouble conditions, and
system 128 event buffer
-remote access can be controlled by owner to
prevent unauthorized access to system
Power supply
-550mA @ 12.5VDC auxiliary power (400mA for
UL applications)
-positive temperature coefficient (PTC)
protected battery, AUX, and Bell output
-electronic protection of KEYBUS
-supervision of AC power loss, low battery,
auxiliary power failure
-internal clock locked to AC power frequency
EEPROM memory
-will not lose programming or system status
on complete AC and battery failure
battery required : 12V, 4 Ah, rechargeable
sealed lead acid
transformer required : 16.5VAC, 40VA
System Operation
2 system partitions… 2 account numbers
-each partition acts as a separate alarm
system with any number of zones, user codes,
keypads and individually programmable
features
38 - 4 or 6 digit access codes
-32 user codes, 1 system master code, 2
partition master codes, 2 duress codes, and
1 maintenance code
automatic arming by partition-each partition
may be programmed to auto-arm at its own
time each day
keypad lockout
-panel can be programmed to lockout keypad
if a series of incorrect access code entries
are made
'quick arm' and 'quick exit' -allows users
to arm and exit easily
'stay/away' zones and 'stay' arming
-security of perimeter arming while premise
is occupied
door chime -programmable by zone
-monitor a door by having keypad beep when
the door is opened and again when door is
closed
128 event buffer
-all events automatically stored with time
and date stamp to buffer
-events can be printed on-site using the
PC5400 serial printer interface module,
viewed through an
LCD Keypad, or viewed and printed via PC
using DLS software
Full Supervision
The system continuously monitors the
following trouble conditions :
-AC power failure
-trouble by zone
-telephone line trouble
-low battery
-bell output trouble
-loss of internal clock
-tamper by zone
-fail to communicate
-aux power supply fault
-module fault (supervisory or tamper)
-camera troubles (on PC5015 with Downlook)